Technical information and report index
Reviewed brochure parameters, actual report-cover references, installation information and missing evidence for HUATONG facade-panel procurement.
Evidence reviewed: 2026-10-09. Document revisions and test scope must be confirmed for the selected configuration.
Parameters supported by the supplied material
| Item | Source information | Source and scope |
|---|---|---|
| Ceramic facing | 6–8 mm | Facing layer only; brochure printed p. 03 |
| Natural stone facing | 8–10 mm | Facing layer only; brochure printed p. 04 |
| Coated calcium-silicate board | Thickness not supplied | Brochure printed p. 05; 29 coating entries |
| Core types | Rock wool, phenolic foam, EPS | Brochure printed p. 01; combination to be confirmed |
| Mass / thermal / fire performance | Configuration data not supplied | Cannot infer complete-panel performance from core names or a report cover |
The brochure’s printed p. 06 comparison of 120/40 kg, 3–8 cm thickness and energy/cost figures does not identify the complete configuration, area basis or test conditions. These illustrations are not converted into kg/m², R-values or universal supply commitments.
Test-document index
| Field | Information readable on the supplied cover |
|---|---|
| Readable report number | FH2021YB0384 |
| Issuer name on cover | 国家建筑防火产品安全质量监督检验中心 |
| Applicant / inspected entity / manufacturer | 廊坊富乐斯保温材料有限公司; HUATONG is not named in these fields |
| Sample on cover | 热固复合聚苯乙烯泡沫保温板(聚合聚苯板) — an insulation board |
| Sample specification on cover | 1200 × 600 × 100 mm; G type, 060 grade; this report’s specimen only |
| Received / tested / issued | 2021-05-10 / 2021-05-11 to 2021-05-26 / 2021-05-26 |
| Available scope | Page 1 of 3 only. Data pages, supply-chain relationship and complete-panel applicability are not supplied. |
View the actual report-cover image
Any conclusion on the cover concerns the received insulation-board specimen. It does not establish the fire classification of HUATONG’s three panel series, the assembled wall or approval in East Asia, Southeast Asia or North America. The full report, test method and specimen relationship require confirmation.
Installation information and guideline reference
- Adhesive-plus-anchor method overview
- Opening, corner and plinth illustrations in HTML/SVG
- Eight-step illustrated site process
- RISN-TG028-2017 guideline-cover image
The cover identifies the Technical guideline for external thermal insulation engineering based on insulated decorative panel, RISN-TG028-2017. Only the cover is supplied; the full text is not offered for download, and the cover alone does not prove drafting participation. Site work requires reviewed project details, fixing design and controlled installation documents.
The existing SVGs illustrate the build-up; they are not dimensioned construction drawings with approved loads and revisions. Public DWG/PDF originals have not been supplied.
Evidence gaps and project review
Required next: panel mass in kg/m²; core thickness, density and conductivity; panel/wall thermal values and conditions; complete fire, wind-load, bond and weathering reports; format tolerances, anchor specifications and drawing revisions; MOQ, lead time, samples, packaging and delivery terms.
Use the existing enquiry form to state the destination market, building use and desired configuration. Document review does not replace local project design or approval.
Send drawings and document requirementsSource records
- Brochure printed p. 03 — Ceramic insulated facade panels
- Brochure printed p. 04 — Natural stone insulated panels
- Brochure printed p. 05 — Coated calcium-silicate insulated panels
The manufacturer brochure has no supplied edition date. Excerpts from project pages 08/09 appear in the individual case pages. The original brochure is not offered as a public PDF because it also contains historical contact information. Parameters are limited to the evidence scope listed here and the confirmed project configuration.